AIX5300小机报错 COMMUNICATION PROTOCOL ERROR解决方法
日志查看errpt报错信息如下:
LABEL: ISCSI_ERR10
IDENTIFIER: 1364248E
Date/Time: Sat Mar 2 19:36:14 BEIST 2013
Sequence Number: 247343
Machine Id: 00C97D104C00
Node Id: DBSERVER_A
Class: H
Type: TEMP
Resource Name: iscsi2
Resource Class: driver
Resource Type: qliscsi
Location: U7879.001.DQD404W-P1-C4-T1
Description
COMMUNICATION PROTOCOL ERROR
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
LABEL: ISCSI_ERR10
IDENTIFIER: 1364248E
Date/Time: Sat Mar 2 19:36:14 BEIST 2013
Sequence Number: 247342
Machine Id: 00C97D104C00
Node Id: DBSERVER_A
Class: H
Type: TEMP
Resource Name: iscsi2
Resource Class: driver
Resource Type: qliscsi
Location: U7879.001.DQD404W-P1-C4-T1
Description
COMMUNICATION PROTOCOL ERROR
Recommended Actions
PERFORM PROBLEM DETERMINATION PROCEDURES
Detail Data
SENSE DATA
0000 0000 0000 0083 0000 0005 0301 0000 0000 0000 0000 0000 0000 0000 0000 0000
0A01 026E 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
解决思路:
首先不能凭借 日志就完全肯定 就是HBA卡报错,一步步排错如下:
1,先执行 lsdev -Cc adapter
2,lsslot -c slot
通过这两个命令看下是否激活状态 如果有LPAR 在本机已分配就是激活 未分配 就不是激活的
3,看看存储和本地的多路径 lspath 查看下
日志有具体槽位的报错 ,看着是链路错误 不是卡的错误 具体查看一下HMC日志
通过以上几种方法基本可以定位
4 经常报磁盘错误 有可能是多路径的错误 并不是HBA 查看Hba卡的状态就知道了
美高森美公司美高森美推出的Adaptec 智能存储解决方案可以为 SDS、冷存储和企业应用提供高性能、低功耗且可靠的解决方案。
本文以Emulex HBA作为示例HBA,分享Linux下HBA卡的连接配置过程。
这篇文章的“核心HBA”,是用以连接存储系统为主流的SAS HBA卡,而不是(更准确的说是连接交换机的)iSCSI HBA、FC HBA等。
实例说明Linux系统下HBA卡的常用基本操作,包括如何通过命令或日志查找HBA,如何查找WWN以及设置永久绑定,以及HBA卡安装完成之后如何识别存储设备。
下面介绍对HBA升级扩展或替换的7个原则和注意事项,HBA卡的健康与否直接关系到网络的连通性,影响网络速度,有时候不合适的HBA卡驱动还会造成主机系统的错误甚至是宕机,为了避免这些问题,选择升级的时候,一定要谨慎再谨慎,要确保对系统做一个备份。